Roof Rock Wool Board

Roof Rock Wool Board

Our Roof Rock Wool Board is a basalt-based mineral fiber insulation board designed for metal roofs and other roof insulation systems. Installed above the structural roof deck and beneath the waterproofing layer, it provides thermal insulation, non-combustible protection, and sound absorption for industrial and commercial buildings.
Send Inquiry

Product Overview

 

Our Roof Rock Wool Board is a basalt-based mineral fiber insulation board designed for metal roofs and other roof insulation systems. Installed above the structural roof deck and beneath the waterproofing layer, it provides thermal insulation, non-combustible protection, and sound absorption for industrial and commercial buildings. 

 

Technical Specifications

 

Parameter

Specification

Product Name

Roof Rock Wool Board

Raw Material

Basalt

Manufacturing Process

High-temperature melting, centrifugal fiberization and curing

Density

55–180 kg/m³

Combustion Performance

Class A, Non-combustible

Product Form

Rigid Insulation Board

Thickness

Commonly 50–100 mm for metal roof applications

 

Key Product Features

 

Class A Fire Resistance

Made from inorganic basalt fibers through high-temperature melting and centrifugal fiberization, our board achieves Class A non-combustible performance, helping limit fire spread.

Resists Compression

Its rigid fiber structure provides compressive resistance during roof installation and maintenance. Higher-density grades offer greater load resistance.

Absorbs Sound

Its interlaced mineral fibers trap sound energy, helping reduce noise transmission through the roof.

 

Roof System Composition

 

Our Roof Rock Wool Board is installed as part of a multi-layer roof assembly. A typical metal roof configuration includes: 

Roof Layer

Material / Function

Structural Layer

Profiled steel sheet

Vapor Barrier

Polyester film or aluminum foil

Insulation Layer

Roof Rock Wool Board

Waterproofing Layer

PVC, TPO or modified bitumen membrane

Protective Layer

Selected according to roof design

 

The insulation board is positioned between the roof deck and waterproofing layer. The complete configuration is determined by the roof design and project requirements. 

 

Applications

 

 

Metal Roofs

Installed above profiled steel sheets to provide thermal insulation and non-combustible protection for industrial buildings and warehouses.

Flat Roofs

Used as the insulation layer beneath waterproofing systems in commercial and industrial buildings.

Industrial Building Roofs

Suitable for factory and workshop roof assemblies where thermal insulation and fire performance are important selection criteria.

 

Density & Thickness Selection

 

Non-Walkable Roofs

Density of 80–100 kg/m³ is suitable for general non-walkable roof insulation requirements.

Walkable or Maintenance Roofs

Density of 120 kg/m³ or above is recommended where roof maintenance access is required. Walkway panels are used to distribute foot traffic loads and reduce local compression.

Metal Roof Insulation

Common thickness options are 50–100 mm. Final thickness is selected according to the project's thermal calculation.

High-Humidity Roofs

A vapor barrier is incorporated into the roof assembly to limit moisture migration into the insulation layer.

 

Quality Control

 

Density Verification

Weigh representative samples and measure their dimensions to calculate bulk density. Results are checked against the specified density grade to ensure batch consistency.

Dimensional Inspection

Measure board length, width and thickness using calibrated measuring tools. Dimensions are checked against order requirements to reduce fitting problems during installation.

Compressive Performance Testing

Test representative samples using a compression testing machine to evaluate resistance to deformation under load. Results are compared with the agreed technical requirements.

Visual Inspection

Check board surfaces and edges for cracks, uneven fiber distribution and visible damage. Non-conforming boards are identified before packing.

Final Order Verification

Verify product grade, dimensions, quantity, labels and packaging against the purchase order before dispatch, helping prevent specification and delivery discrepancies.

 

Supply Information

 

MOQ: 1 × 20ft container for standard export orders; trial quantities negotiable.
Sample: Free samples available; freight collected.
Lead Time: 15–20 working days after deposit and specification confirmation.
Packaging: PE-wrapped bundles with export protection for sea transportation.
Payment Terms: T/T, 30% deposit and 70% balance before shipment.
Shipping Terms: FOB, CIF or CFR. 

 

Storage & Handling

 

Keep Dry: Store boards in a dry, covered and well-ventilated area to prevent moisture exposure.
Protect from Damage: Keep products in their original packaging and away from water, impact and compression.
Store Off the Ground: Place boards on pallets or raised supports, avoiding direct contact with wet floors.
Handle Carefully: Avoid dragging or dropping boards to prevent edge damage and deformation. 

 

FAQ

 

Q: What technical data should I check when purchasing Roof Rock Wool Board?

A: Review thermal conductivity, compressive strength, water absorption and dimensional stability. These values help engineers evaluate insulation efficiency and suitability for the specified roof design.

Q: How do I evaluate the compressive strength of roof rock wool board?

A: Compare the compressive strength test results with the roof system's design loads and project specifications. For maintenance-access roofs, also consider the load distribution provided by walkway systems.

Q: Can Roof Rock Wool Board be cut to fit roof edges and penetrations?

A: Yes. The boards can be cut with suitable insulation cutting tools to fit roof edges, drainage outlets, pipe penetrations and other irregular areas. Accurate cutting helps minimize gaps around details.

Q: How can I prevent moisture from affecting roof rock wool insulation?

A: Coordinate the vapor barrier, insulation layer and waterproofing membrane as a complete roof assembly. Proper joint treatment and waterproofing details help limit moisture entry and maintain insulation performance.

Q: What information is needed for a project-specific quotation?

A: Provide the required board dimensions, density, thickness, estimated quantity, roof application, delivery destination and any project-specific technical requirements. This allows us to assess the specification and prepare a quotation.

Q: Can you provide technical documents for engineering approval?

A: We can coordinate product specifications, technical data sheets and relevant test documentation for project review. Document requirements can be confirmed against the applicable project standards before ordering.

Hot Tags: roof rock wool board, China roof rock wool board manufacturers, suppliers, factory, calcium silicate composite board, fire rated composite insulation board, Fire Rated Foil Faced Rock Wool Blanket, high density rockwool slab, rock wool calcium silicate composite board, rockwool composite panels