Fire Rated Duct Wrap
Fire Protection Wraps for Different Duct Requirements
Fire rated duct wrap is used to protect HVAC and smoke-control ductwork against heat exposure and fire spread. Depending on the duct configuration, required fire performance, and installation conditions, different wrap materials and constructions may be specified.
Langfang Yafeng Energy-Saving Technology Co., Ltd. supplies several types of duct fire protection and high-temperature insulation wraps for industrial and building applications.
-
Reinforced Duct Fire Protection WrapOur Reinforced Duct Fire Protection Wrap combines an aluminum silicate needled blanket or other specified fire-protection layers with a reinforced outer facing. It is designed for fire protection...read more
-
Fire Rated Silicate WrapFire Rated Silicate Wrap is a versatile board or blanket-based material utilizing aluminum silicate or composite layers, designed to deliver fire protection, thermal insulation, and condensation...read more
-
Flexible Duct Fire WrapOur Flexible Duct Fire Wrap is a flexible fire protection wrapping material for smoke exhaust and other specified duct systems. It uses an aluminum silicate needled blanket core with foil or...read more
-
Fire Barrier Duct WrapOur Fire Barrier Duct Wrap is a flexible fire protection system for ventilation and smoke-control ductwork. It uses an aluminum silicate needled blanket with foil or reinforced facing, with...read more
-
Aluminum Silicate Fire WrapAluminum Silicate Fire Wrap is a flexible, needled ceramic fiber blanket designed to conform to curved surfaces and tight spaces, providing essential fire protection and thermal insulation for hot...read more
Fire Rated Duct Wrap Product Range
|
Product |
Main Characteristics |
Typical Applications |
|
Reinforced Duct Fire Protection Wrap |
Mineral fiber insulation with a reinforced outer facing for improved surface protection and handling resistance |
Smoke ducts, duct sections exposed to frequent handling, and industrial ductwork |
|
Fire Rated Silicate Wrap |
Silicate-based insulation supplied in board or blanket form |
Duct casings, equipment shells, partitions, and service passages exposed to heat |
|
Flexible Duct Fire Wrap |
Flexible insulation with foil or reinforced facing for wrapping around irregular duct sections |
Ducts with elbows, flanges, hanger rods, and short offsets |
|
Fire Barrier Duct Wrap |
Duct enclosure wrap intended for applications requiring fire resistance as part of a tested system |
Ventilation and smoke-control ducts passing through fire-rated compartments |
|
Aluminum Silicate Fire Wrap |
Lightweight high-temperature fiber insulation for thermal protection |
Hot ducts, furnace exhaust sections, expansion zones, and steel surfaces near heat sources |
Match the Wrap to Your Duct Application
|
Duct Application |
Main Requirement |
Selection Considerations |
|
HVAC supply and return ducts |
Fire protection or thermal insulation, as specified by the project |
Required fire rating, duct dimensions, and insulation thickness |
|
Smoke extraction ducts |
Fire resistance under specified smoke extraction conditions |
Applicable EN 1366 test scope, required rating, and installation configuration |
|
Ducts crossing fire compartments |
Maintain the specified fire separation |
Tested duct enclosure and compatible penetration firestop details |
|
Industrial exhaust ducts |
Thermal protection under operating conditions |
Exhaust temperature, material type, and service life requirements |
|
Commercial kitchen grease ducts |
Fire-resistant grease duct enclosure |
Specific grease duct test documentation, such as applicable ASTM E2336 or UL 2221 system evidence |
Fire Resistance & Thermal Performance
|
Performance Item |
What Buyers Need to Confirm |
|
Fire resistance |
Whether the complete assembly has a 1-hour or 2-hour test or classification result for the intended application |
|
Service temperature |
Maximum continuous operating temperature for the selected insulation material |
|
Combustibility |
Product classification and applicable test results |
|
Smoke and droplet performance |
Relevant test evidence where required by the project |
|
Thermal conductivity |
Product-specific value measured at a stated mean temperature |
Applicable International Standards
|
Standard |
Application |
|
EN 1366-1 |
Ventilation ducts |
|
EN 1366-8 |
Smoke extraction ducts with fire-resisting ducts |
|
EN 1366-9 |
Single-compartment smoke extraction ducts |
|
ASTM E2336 |
Fire-resistive grease duct enclosure assemblies |
|
UL 2221 |
Fire-resistive grease duct enclosure assemblies |

Fire protection wrap performance depends on continuous coverage across all physical components and structural nodes.
Conforming Layouts & Duct Geometries
Rectangular, Square & Round Structures: Flexible blanket profiles conform around flat sheet metal surfaces, sharp radiused corners, and circular spiral piping.
Fittings & Transitions: Easily field-cut to fit tightly over elbows, tees, offset sections, reducers, and branch connections without forming thermal gaps.
Critical Construction Nodes & Accessories
Joint Overlaps: All longitudinal and transverse blanket joints require a minimum lap width sealed with matching foil tape to prevent heat bridging.
Mechanical Fastening: Secured using high-density weld pins, speed clips, stainless steel wire, or banding straps tied at specified centers to hold wraps firmly against substrates under high heat.
Penetration & Support Protection: Wall and floor penetrations require intumescent sealants and mineral fiber packing. Trapeze hangers and threaded support rods must be insulated or sized according to fire design standards.
Insulation Materials and Facing Options
|
Material or Construction |
Main Characteristics |
|
Inorganic mineral fiber |
Fibrous insulation structure with thermal insulation properties |
|
AES fiber |
High-temperature insulation material available in flexible blanket or board form |
|
Refractory ceramic fiber (RCF) |
Lightweight insulation material for high-temperature environments |
|
Aluminum foil facing |
Provides an outer facing and can serve as a vapor-control layer when the product construction and joints are suitable |
|
Reinforced glass cloth facing |
Adds surface reinforcement and improves handling characteristics |
Technical Specifications and Product Selection
|
Specification |
Information to Confirm |
|
Core material |
Mineral fiber, AES fiber, refractory ceramic fiber, or other specified material |
|
Product form |
Blanket, flexible wrap, or board |
|
Outer facing |
Aluminum foil, reinforced glass cloth, or other available facing |
|
Thickness |
Available thickness and required installation thickness |
|
Density |
Product-specific nominal density |
|
Dimensions |
Standard width and length, or customized dimensions |
|
Fire resistance |
Applicable rating supported by test reports or classification documents |
|
Service temperature |
Product-specific continuous or maximum service temperature |
|
Thermal conductivity |
Value measured at the specified mean temperature |
|
Packaging |
Roll, bundle, carton, or project-specific packaging |
Manufacturing and Custom Supply Capabilities
Langfang Yafeng Energy-Saving Technology Co., Ltd. was established in 2018 and operates a 25,000 m² manufacturing facility with more than 120 employees.
The company supplies insulation materials for industrial and building applications, with manufacturing and processing options for different project specifications.
Available customization options for duct wrap products may include:
Thickness: Product thickness according to the selected material and application.
Dimensions: Customized width and length for project requirements.
Facing: Available foil, reinforced glass cloth, or other product-specific facing options.
Product form: Blanket, flexible wrap, or board, depending on material type.
Packaging: Roll, bundle, carton, or project-specific packaging.
OEM supply: Product labeling and packaging arrangements for eligible orders.
Technical Submittal Documentation & Compliance
To support engineering submittals, contractor approvals, and authority inspections, the following technical documentation is available:
Product Technical Datasheets (TDS): Complete physical properties, density tolerances, and thermal conductivity values.
Fire Test & Compliance Summaries: Test documentation and classification reports detailing fire resistance performance under applicable standards (e.g., EN 1366-1, EN 1366-8, ASTM E2336, UL 2221).
Assembly & Installation Details: Standardized details covering joint overlaps, pin layouts, hanger sleeves, and penetration seals.
Safety Data Sheets (SDS): Material health and environmental compliance documentation for job-site handling.
As one of the most professional fire rated duct wrap manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy high quality fire rated duct wrap for sale here from our factory. For price consultation, contact us.