Fire Rated Duct Wrap

Fire Protection Wraps for Different Duct Requirements

 

Fire rated duct wrap is used to protect HVAC and smoke-control ductwork against heat exposure and fire spread. Depending on the duct configuration, required fire performance, and installation conditions, different wrap materials and constructions may be specified.
Langfang Yafeng Energy-Saving Technology Co., Ltd. supplies several types of duct fire protection and high-temperature insulation wraps for industrial and building applications.

 
  • Reinforced Duct Fire Protection Wrap
    Our Reinforced Duct Fire Protection Wrap combines an aluminum silicate needled blanket or other specified fire-protection layers with a reinforced outer facing. It is designed for fire protection...
    read more
  • Fire Rated Silicate Wrap
    Fire Rated Silicate Wrap is a versatile board or blanket-based material utilizing aluminum silicate or composite layers, designed to deliver fire protection, thermal insulation, and condensation...
    read more
  • Flexible Duct Fire Wrap
    Our Flexible Duct Fire Wrap is a flexible fire protection wrapping material for smoke exhaust and other specified duct systems. It uses an aluminum silicate needled blanket core with foil or...
    read more
  • Fire Barrier Duct Wrap
    Our Fire Barrier Duct Wrap is a flexible fire protection system for ventilation and smoke-control ductwork. It uses an aluminum silicate needled blanket with foil or reinforced facing, with...
    read more
  • Aluminum Silicate Fire Wrap
    Aluminum Silicate Fire Wrap is a flexible, needled ceramic fiber blanket designed to conform to curved surfaces and tight spaces, providing essential fire protection and thermal insulation for hot...
    read more
 

Fire Rated Duct Wrap Product Range

 

Product

Main Characteristics

Typical Applications

Reinforced Duct Fire Protection Wrap

Mineral fiber insulation with a reinforced outer facing for improved surface protection and handling resistance

Smoke ducts, duct sections exposed to frequent handling, and industrial ductwork

Fire Rated Silicate Wrap

Silicate-based insulation supplied in board or blanket form

Duct casings, equipment shells, partitions, and service passages exposed to heat

Flexible Duct Fire Wrap

Flexible insulation with foil or reinforced facing for wrapping around irregular duct sections

Ducts with elbows, flanges, hanger rods, and short offsets

Fire Barrier Duct Wrap

Duct enclosure wrap intended for applications requiring fire resistance as part of a tested system

Ventilation and smoke-control ducts passing through fire-rated compartments

Aluminum Silicate Fire Wrap

Lightweight high-temperature fiber insulation for thermal protection

Hot ducts, furnace exhaust sections, expansion zones, and steel surfaces near heat sources

 

Match the Wrap to Your Duct Application

 

Duct Application

Main Requirement

Selection Considerations

HVAC supply and return ducts

Fire protection or thermal insulation, as specified by the project

Required fire rating, duct dimensions, and insulation thickness

Smoke extraction ducts

Fire resistance under specified smoke extraction conditions

Applicable EN 1366 test scope, required rating, and installation configuration

Ducts crossing fire compartments

Maintain the specified fire separation

Tested duct enclosure and compatible penetration firestop details

Industrial exhaust ducts

Thermal protection under operating conditions

Exhaust temperature, material type, and service life requirements

Commercial kitchen grease ducts

Fire-resistant grease duct enclosure

Specific grease duct test documentation, such as applicable ASTM E2336 or UL 2221 system evidence

 

Fire Resistance & Thermal Performance

 

 

Performance Item

What Buyers Need to Confirm

Fire resistance

Whether the complete assembly has a 1-hour or 2-hour test or classification result for the intended application

Service temperature

Maximum continuous operating temperature for the selected insulation material

Combustibility

Product classification and applicable test results

Smoke and droplet performance

Relevant test evidence where required by the project

Thermal conductivity

Product-specific value measured at a stated mean temperature

 

Applicable International Standards

 

Standard

Application

EN 1366-1

Ventilation ducts

EN 1366-8

Smoke extraction ducts with fire-resisting ducts

EN 1366-9

Single-compartment smoke extraction ducts

ASTM E2336

Fire-resistive grease duct enclosure assemblies

UL 2221

Fire-resistive grease duct enclosure assemblies

 

Fire Barrier Duct Wrap

 

Duct Geometry, Layouts & Installation Compatibility

Fire protection wrap performance depends on continuous coverage across all physical components and structural nodes.


Conforming Layouts & Duct Geometries
Rectangular, Square & Round Structures: Flexible blanket profiles conform around flat sheet metal surfaces, sharp radiused corners, and circular spiral piping.
Fittings & Transitions: Easily field-cut to fit tightly over elbows, tees, offset sections, reducers, and branch connections without forming thermal gaps.


Critical Construction Nodes & Accessories
Joint Overlaps: All longitudinal and transverse blanket joints require a minimum lap width sealed with matching foil tape to prevent heat bridging.
Mechanical Fastening: Secured using high-density weld pins, speed clips, stainless steel wire, or banding straps tied at specified centers to hold wraps firmly against substrates under high heat.
Penetration & Support Protection: Wall and floor penetrations require intumescent sealants and mineral fiber packing. Trapeze hangers and threaded support rods must be insulated or sized according to fire design standards.

 

Insulation Materials and Facing Options

 

Material or Construction

Main Characteristics

Inorganic mineral fiber

Fibrous insulation structure with thermal insulation properties

AES fiber

High-temperature insulation material available in flexible blanket or board form

Refractory ceramic fiber (RCF)

Lightweight insulation material for high-temperature environments

Aluminum foil facing

Provides an outer facing and can serve as a vapor-control layer when the product construction and joints are suitable

Reinforced glass cloth facing

Adds surface reinforcement and improves handling characteristics

 

Technical Specifications and Product Selection

 

Specification

Information to Confirm

Core material

Mineral fiber, AES fiber, refractory ceramic fiber, or other specified material

Product form

Blanket, flexible wrap, or board

Outer facing

Aluminum foil, reinforced glass cloth, or other available facing

Thickness

Available thickness and required installation thickness

Density

Product-specific nominal density

Dimensions

Standard width and length, or customized dimensions

Fire resistance

Applicable rating supported by test reports or classification documents

Service temperature

Product-specific continuous or maximum service temperature

Thermal conductivity

Value measured at the specified mean temperature

Packaging

Roll, bundle, carton, or project-specific packaging

 

Manufacturing and Custom Supply Capabilities

 

 

Langfang Yafeng Energy-Saving Technology Co., Ltd. was established in 2018 and operates a 25,000 m² manufacturing facility with more than 120 employees.
The company supplies insulation materials for industrial and building applications, with manufacturing and processing options for different project specifications.


Available customization options for duct wrap products may include:
Thickness: Product thickness according to the selected material and application.
Dimensions: Customized width and length for project requirements.
Facing: Available foil, reinforced glass cloth, or other product-specific facing options.
Product form: Blanket, flexible wrap, or board, depending on material type.
Packaging: Roll, bundle, carton, or project-specific packaging.
OEM supply: Product labeling and packaging arrangements for eligible orders.

 

Technical Submittal Documentation & Compliance
To support engineering submittals, contractor approvals, and authority inspections, the following technical documentation is available:
Product Technical Datasheets (TDS): Complete physical properties, density tolerances, and thermal conductivity values.
Fire Test & Compliance Summaries: Test documentation and classification reports detailing fire resistance performance under applicable standards (e.g., EN 1366-1, EN 1366-8, ASTM E2336, UL 2221).
Assembly & Installation Details: Standardized details covering joint overlaps, pin layouts, hanger sleeves, and penetration seals.
Safety Data Sheets (SDS): Material health and environmental compliance documentation for job-site handling.

 

FAQ

 

Q: Are 1-hour and 2-hour fire ratings available?

A: These configurations may be available for specific tested duct enclosure systems. The applicable rating must be confirmed through the relevant test report or classification document.

Q: Can duct wrap replace a fire-rated shaft?

A: A tested duct wrap system may be accepted as an alternative in certain projects. This depends on local building codes, project specifications, and approval of the complete assembly.

Q: Can the wrap be installed around elbows and flanges?

A: Flexible wrap products can accommodate many irregular duct sections. Joint treatment and fastening must follow the applicable installation instructions.

Q: Can these products be used for high-temperature exhaust ducts?

A: Selected products, particularly refractory fiber-based materials, may be suitable for elevated-temperature applications. Confirm the continuous service temperature and material specification before selection.

Q: What information is needed for a quotation?

A: Please provide the product type, application, required fire resistance rating, applicable standard, duct dimensions, insulation thickness, facing preference, order quantity, and delivery destination. Drawings or BOQs are helpful for project orders.

As one of the most professional fire rated duct wrap manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy high quality fire rated duct wrap for sale here from our factory. For price consultation, contact us.